Thermal power station in the Middle East

PROBLEM:

The customer encountered various problems on one of the main conveyors taking coal from the hoppers to the boiler rooms:

  • Overflowing of material => employees required to carry out regular cleaning & substantial maintenance of station rollers
  • Polluting & explosive atmosphere

OBJECTIVE:

Reduce loss of products & cleaning/maintenance time and purify the atmosphere.

Conveyor taking coal

SOLUTION:

15 m of wide (1000 mm) LIFTUBE from a raise equipped with a 2 m hopper hood.

RESULT:

The sealing of the conveyor was optimised and enabled the customer to reduce dust emissions, loss of material and therefore the cleaning/maintenance time by 95%.


Call