Maintenance of Airchoc

MAINTENANCE AIR CANNONTHE MAINTENANCE OF OUR AIRCHOC® AIR CANNONS TANKS

In order to operate on an AIRCHOC®, you must :

  • Close the group’s air valve and possibly other groups in the work area
  • Switch off the individual Airchoc® air cannon’s supply (stop/isolation valve)
  • Manually trigger and check the air cannon’s firing (if possible see the indications)
  • Open the quick exhaust valve to eliminate condensation due to temperature drops and pressure increase
  • Repeat the process on the whole pool of Airchoc® air cannons in the area before dismantling

Prerequisite for a proper AIRCHOC® operation :

  • Sufficient air pressure
  • Clean air
  • Supply and exhaust valve
  • Suspension collar
  • Electricity, voltage

Prerequisites for a good elimination of clogging