Build-ups on the preheating tower at the level of: the kiln inlet, the smoke box, the gas ducts, the bypass which represent 8 hours of cleaning per day (high pressure and cardox).
Flour (future clinker then cement)
Eliminate the build ups that disrupt the industrial process and reduce production capacity
Installation of 85 AIRCHOC® DN150 with remote solenoid valves and 1 MACSYS.